流光放电等离子体污水消毒灭菌
doi: 10.13205/j.hjgc.201503011
STERILIZATION FOR WASTEWATER BY STREAMER CORONA PLASMAS
-
摘要: 采用流光放电等离子体技术,研究放电电压、大肠杆菌初始浓度、反应器类型对大肠杆菌灭杀的影响,并将流光放电等离子体与臭氧灭菌进行效果对比。结果表明:当在水槽装置中,处理温度为室温,大肠杆菌初始浓度为480 000个/L,放电时间为45 min,水样体积V=50 L,气量Q=8 m3/h,放电电压为30 k V,电流I=11 m A时大肠杆菌的去除率达到99%。流光放电等离子体与臭氧去除污水中大肠杆菌的能力都较强,与臭氧灭菌相,比流光放电等离子体杀菌经济成本低廉许多。Abstract: The discharge voltage,initial concentration of Escherichia coli,different test device were investigated while treating Escherichia coli from a wastewater treatment plant by streamer corona plasmas; and researchers compared the result of streamer corona plasmas and ozone disinfection. The results showed that the sterilization rate of Escherichia coli was 99% when initial concentration of Escherichia coli was 480 000 per litre,discharge time was 45 min,volume of water sample was 50 L,gas flow rate was 8 m3 /h,discharge voltage was 30 kV,the current was 11 mA in the tank at the room temperature; streamer corona plasmas and ozone disinfection had high sterilization capability,but the economic cost of streamer corona plasmas was cheaper than ozone disinfection.
-
Key words:
- plasmas /
- streamer corona /
- sterilization /
- Escherichia coli
点击查看大图
计量
- 文章访问数: 302
- HTML全文浏览量: 17
- PDF下载量: 229
- 被引次数: 0