EXPERIMENTAL STUDY ON TREATMENT OF PHENOL WASTEWATER BY THREE-DIMENSIONAL ELECTRODE FENTON METHOD
-
摘要: 采用三维电极电Fenton法对制陶工艺含酚废水进行处理,选择pH、时间、电压、FeSO4·7H2O投放量、通气量、电解质投放量以及电极间距为单因素,设置不同水平,研究苯酚和COD的去除效果,同时探讨了该方法的电化学能耗。结果表明:在pH为3,电压为15 V,FeSO4·7H2O投放量为1.8 g/L,通气量为9 L/min,Na2SO4粉末投加量为1.0 g/L,电极间距取10 cm,反应120 min的条件下,废水中苯酚及COD去除率可分别达到94.13%和86.67%,处理效果明显,且能耗较二维电极大大减少,可为该方法在含酚废水处理领域的应用提供参考。Abstract: Three-dimensional electrode electro-Fenton method was used to treat phenol-containing wastewater from pottery process. The removal efficiency of phenol and COD was studied with the single factor of pH, time, voltage, FeSO4·7H2O dosage, ventilation, electrolyte dosage and electrode spacing selected and setted at different levels. The electrochemical energy consumption of the method was also discussed. The results showed that under the conditions of pH of 3, voltage of 15V, FeSO4·7H2O dosage of 1.8 g/L, ventilation of 9 L/min, Na2SO4 powder dosage of 1.0 g/L, electrode spacing of 10 cm and reaction time of 120 min, the removal rates of phenol and COD in wastewater could reach 94.13% and 86.67% respectively. The treatment effect was obvious and the energy consumption was much lower than that of two-dimensional electrodes. It could provide reference for practical application.
-
Key words:
- three-dimensional electrode /
- Fenton /
- phenol /
- COD /
- removal rate
-
TOMAT R,RIGO A.Electrochemical oxidation of toluene promoted by OH radicals[J].Journal of Applied Electrochemistry,1984,14(1):1-8. OTURAN M A. An ecologically effective water treatment technique using electrochemically generated hydroxyl radicals for in situ destruction of organic pollutants:application to herbicide 2, 4-D[J].Journal of Applied Electtrochemistry, 2000, 30(4):475-482. BRILLAS E, CALPE J C, CASADO J.Mineralization of 2, 4-D by advanced electrochemical oxidation processes[J].Water Research, 2000, 34(8):2253-2262. 孙寿联,李建丰.复极性三维电极-电芬顿耦合法处理苯酚废水的实验研究[J].辽宁化工,2016,45(3):270-271,275. LI Y F,GUAN Y Z,TAO C C.Influencing factors research of phenolwastewater treatment by cathode electro-Fenton method[J]. Applied Informatics and Communication, 2011,224:726-733. KEKZ R, STUCKI S, CARCER B. Electrchemical waste water treatment using hige overvoltage anodes[J].Journal of Applied Electrochemistry,1991,21(5):14-22. 叶德宁,应迪文,贾金平.活性炭纤维电极在水处理中的应用及进展[J].中国给水排水,2007,23(18):20-23. 赵敏.三维电极法深度处理制药废水的研究[D].河南:郑州大学,2012. 何祥,傅金祥,李晓彤,等.三维电-Fenton法处理垃圾浓缩液试验研究[J].工业水处理,2018,38(1):65-69. 吴娜娜,钱虹,郑璐,等.三维电极电-Fenton法处理孔雀石绿染料废水研究[J].沈阳建筑大学学报(自然科学版),2018,34(1):183-192. 许晓霞,王建中,孙浩,等.三维电极-Fenton法处理甲醛模拟废水试验研究[J].工业用水与废水,2012,43(5):23-27. 董亚荣,王立栋,张尊举,等.三维电极-电Fenton法深度处理造纸废水[J].中国造纸,2016,35(7):35-38. 周蕾,周明华.电芬顿技术的研究进展[J].水处理技术,2013,39(10):6-11. 李亚峰,方明,管玉琢,等.活性炭纤维阴极三维电Fenton法深度处理焦化废水[J].沈阳建筑大学学报(自然科学版),2011,27(6):1163-1167. 魏旺,孟冠华,刘宝河,等.三维电极电解法处理氨氮废水的研究[J].工业水处理,2018,38(8):74-77. 高敏,张艺荣,赵景龙,等.双铁电极电解除磷技术初探[J].水处理技术,2014,40(6):39-42. 代理.三维电极协同紫外光催化法处理焦化废水的试验研究[D].重庆:重庆大学,2012. 魏婕.三维电极法处理亚甲基蓝模拟废水的研究[D].绵阳:西南科技大学,2015.
点击查看大图
计量
- 文章访问数: 281
- HTML全文浏览量: 41
- PDF下载量: 22
- 被引次数: 0