In order to improve the particle collection efficiency of the electrostatic precipitator ( ESP) ,the bipolar charged
transverse-plate ESP is proposed. The collection performances of this bipolar charged transverse-plate ESP were compared with
the ordinary ESP experimentally at room temperature and pressure. The sinter dust with 25. 405 m mass median diameter was
used for the test particulate. The pressure loss of the bipolar charged transverse-plate ESP was about 30% higher than that of
the ordinary one. The voltage current characteristics of the bipolar charged transverse-plate ESP was superior to the ordinary
ESP. The collection efficiency of the bipolar charged transverse-plate ESP was also much greater than that of the ordinary ESP
when the electric field in the range 2. 1 kV/cm to 3. 2 kV/cm and the velocity in the range 1. 0 m/ s to 1. 5 m/ s were set up
respectively in this experiment.