Source Jouranl of CSCD
Source Journal of Chinese Scientific and Technical Papers
Included as T2 Level in the High-Quality Science and Technology Journals in the Field of Environmental Science
Core Journal of RCCSE
Included in the CAS Content Collection
Included in the JST China
Indexed in World Journal Clout Index (WJCI) Report
Volume 38 Issue 4
Apr.  2020
Turn off MathJax
Article Contents
LI Jun-qi, ZHANG Shan, LI Xiao-jing, SUN Yao. A STUDY ON THE HARM AND CONTROL COUNTERMEASURES OF THERMAL POLLUTION FROM STORMWATER RUNOFF[J]. ENVIRONMENTAL ENGINEERING , 2020, 38(4): 32-38. doi: 10.13205/j.hjgc.202004007
Citation: LI Jun-qi, ZHANG Shan, LI Xiao-jing, SUN Yao. A STUDY ON THE HARM AND CONTROL COUNTERMEASURES OF THERMAL POLLUTION FROM STORMWATER RUNOFF[J]. ENVIRONMENTAL ENGINEERING , 2020, 38(4): 32-38. doi: 10.13205/j.hjgc.202004007

A STUDY ON THE HARM AND CONTROL COUNTERMEASURES OF THERMAL POLLUTION FROM STORMWATER RUNOFF

doi: 10.13205/j.hjgc.202004007
  • Received Date: 2019-10-20
  • In urbanized areas, stormwater runoff carries heat enriched in the impervious surface and is discharged into the receiving water body, causing thermal pollution. While we are now in shortage of research on the harm of thermal pollution form stormwater runoff, and the controlling standards and technical measures. The causes of thermal pollution from stormwater runoff, and its impact on aquatic organisms and the water environment were elaborated. The common parameters for evaluating thermal pollution load, policy standards and technical measures for controlling thermal pollution of stormwater runoff were analyzed. A quantitative calculation method for thermal pollution load reduction in stormwater facilities, projects or catchment areas was proposed. The applicability analysis of the control efficiency of thermal pollution by current green stormwater source reduction facilities in China was carried out. The countermeasures and suggestions for the prevention and control of thermal pollution load of stormwater runoff were also proposed based on the actual situation in China.
  • loading
  • GALLI J. Thermal Impacts Associated with Urbanization and Stormwater Best Management Practices[M]. Annapolis, MD:Maryland Department of the Environment, 1991.
    SATTAR A M A, GHARABAGHI B, SABOURI F, et al. Urban stormwater thermal gene expression models for protection of sensitive receiving streams:urban stormwater thermal assessment and design guidance tool[J]. Hydrological Processes, 2017, 31(13):2330-2348.
    FERGUSON B, FISHER K, GOLDEN J, et al. Reducing urban heat islands:compendium of strategies-cool pavements[J]. Cooling, 2008, 39.
    ARMOUR C L. Guidance for evaluating and recommending temperature regimes to protect fish[R]. U.S Fishing and Wildlife Service Biological Report, 1991,90:1-13.
    刘晓晖. 温度和铜对鲤鱼肝脏细胞超微结构的影响[D]. 长春:东北师范大学, 2006.
    王云彪. 热影响下鲤鱼Hsp70组织特异性表达和应激反应[D]. 长春:东北师范大学, 2008.
    WHITELAW K, SOLBE J F. River catchment management:an approach to the derivation of quality standards for farm pollution and storm sewage discharges[J]. Urban Discharges & Receiving Water Quality Impacts, 1989, 21(8/9):145-158.
    李思远,管运涛,陈俊,等. 苏南地区合流制管网溢流污水水质特征分析[J]. 给水排水, 2015, 51(增刊1):344-348.
    SABOURI F, GHARABAGHI B, MAHBOUBI A A, et al. Impervious surfaces and sewer pipe effects on stormwater runoff temperature[J]. Journal of Hydrology, 2013, 502(Complete):10-17.
    KIESER M S, FANG A F, SPOELSTRA J A. Role of urban stormwater best management practices in temperature TMDLs[J]. Proceedings of the Water Environment Federation, 2003(4):1716-1739.
    ROSEEN R M, DIGENNARO N, WATTS A, et al. Preliminary results of the examination of thermal impacts from stormwater BMPs[C]//RICHARD N. World Environmental and Water Resources Congress 2010:Challenges of Change. Providence:American Society of Civil Engineers, 2010:3424-3451.
    RAU B. Washington's water quality management plan to control nonpoint sources of pollution[R]. Olympia, Washington.:Washington State Department of Ecology Water Quality Program, 2015.
    Tetra Tech US EPA, Inc. Water Quality Assessment and TMDLs for the Dearborn River Planning Area[M]. Helena, MT:Montana Operations Office, 2005:53.
    City of Portland Environmental Services. TMDL Implementation Plan for the Willamette River & Tributaries[M]. City of Portland, Oregon:2019:29.
    US EPA. National Management Measures to Control Nonpoint Source Pollution from Urban Areas[M]. Washington, DC:United States Environmental Protection Agency Office of Water, 2005.
    US EPA. Quality Criteria for Water 1986[M]. Washington, DC:Office of Water Regulations and Standards, 1986:278-288.
    ANDERSON R, SCHNEIDER D. Wenatchee River Watershed Temperature Total Maximum Daily Load Water Quality Improvement Report[R]. Olympia:Washington State Department of Ecology Water Quality Program Central Regional Office, 2007, 22.
    LI J Q, GONG Y W, LI X J, et al. Urban stormwater runoff thermal characteristics and mitigation effect of low impact development measures[J]. Journal of Water & Climate Change, 2019,10(1):53-62.
    JONES M P, HUNT W F. Effect of storm-water wetlands and wet ponds on runoff temperature in trout sensitive waters[J]. Journal of Irrigation and Drainage Engineering, 2010, 136(9):656-661.
    LONG D L, DYMOND R L. Thermal pollution mitigation in cold water stream watersheds using bioretention[J]. Journal of the American Water Resources Association, 2014, 50(4):977-987.
    HDR. Montana Post-Construction Storm Water BMP Design Guidance Manual[M]. Helena, MT:Montana Department of Environmental Quality, 2017.
    中华人民共和国住房和城乡建设部. 海绵城市建设技术指南:低影响开发雨水系统构建(试行)[M]. 北京:中国建筑工业出版社, 2014.
    国家环境保护总局. 地表水环境质量标准:GB 3838-2002[S].北京:中国环境科学出版社,2002.
    北京市环境保护局. 水污染物综合排放标准:DB11/307-2013[S].北京:中国环境科学出版社,2013.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (204) PDF downloads(12) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return