The treatment for PM2. 5 has been paid more and more attention all around the world for its characteristics,such as
small size,strong adsorption ability,long transportation range,great effect on atmosphere and difficulties in trapping . With
silicon carbide ceramic membrane tube coated with alumina ( porosity: 28. 16%,the average pore diameter: 20 μm,filter
area: 0. 28 m2 ) as filter element,an experimental device was set up for trapping PM2. 5 . The relationship between the filter
time,flux and pressure drop,collection efficiency,cleaning pressure and cleaning time were studied. The results showed that
the flux reduced gradually,the pressure drop and the collection efficiency increased with the filter time,and the collection
efficiency for PM2. 5 was up to 99. 9%. The optimization parameters for membrane fouling control were the cleaning pressure 0. 8
MPa,the cleaning interval 10 min and the cleaning time 14 s,respectively.