Zhao Xuelian Lou Gaobin Li Zonghui Liu Jie Liu Jinquan Jiang Anping Wang Kai Ren Yanqiang Qu Jiayu, . STUDY ON SEWAGE TREATMENT OF GEL-EMBEDDED NITROBACTERIACARRIERS AT LOW TEMPERATURE[J]. ENVIRONMENTAL ENGINEERING , 2015, 33(3): 21-24. doi: 10.13205/j.hjgc.201503005
Citation:
Zhao Xuelian Lou Gaobin Li Zonghui Liu Jie Liu Jinquan Jiang Anping Wang Kai Ren Yanqiang Qu Jiayu, . STUDY ON SEWAGE TREATMENT OF GEL-EMBEDDED NITROBACTERIA
CARRIERS AT LOW TEMPERATURE[J]. ENVIRONMENTAL ENGINEERING , 2015, 33(3): 21-24. doi: 10.13205/j.hjgc.201503005
Zhao Xuelian Lou Gaobin Li Zonghui Liu Jie Liu Jinquan Jiang Anping Wang Kai Ren Yanqiang Qu Jiayu, . STUDY ON SEWAGE TREATMENT OF GEL-EMBEDDED NITROBACTERIACARRIERS AT LOW TEMPERATURE[J]. ENVIRONMENTAL ENGINEERING , 2015, 33(3): 21-24. doi: 10.13205/j.hjgc.201503005
Citation:
Zhao Xuelian Lou Gaobin Li Zonghui Liu Jie Liu Jinquan Jiang Anping Wang Kai Ren Yanqiang Qu Jiayu, . STUDY ON SEWAGE TREATMENT OF GEL-EMBEDDED NITROBACTERIA
CARRIERS AT LOW TEMPERATURE[J]. ENVIRONMENTAL ENGINEERING , 2015, 33(3): 21-24. doi: 10.13205/j.hjgc.201503005
In order to verify the feasibility or reliability of gel-embedded nitrobacteria carriers and to obtain parameters for
engineering application,the gel-embedded nitrobacteria carriers was combined with A/O system’activation condition and
treatment effect was to be studied under the condition of low temperature. The result indicated that the activation time for the
system of activated gel-embedded nitrobacteria carriers was about 10d,no more than 15 d at a low temperature of 13 ℃ to
15 ℃. And under stable operation and load increasing ( increasing to 1. 44 times) stage,the system of gel-embedded
nitrobacteria carriers to treat urban sewage can make an average of below 1 mg /L ammonia nitrogen in the effluent and the
removal rate of ammonia nitrogen was more than 99% under the sludge concentration of 3 000 ~ 3 500 mg /L and dosing rate of
12%. Furthermore,the treatment effect of gel-embedded nitrobacteria carriers combined with A/O system was better than
A/O system under the same conditions.